Field name modifiers and suffixes

Modifiers

The table below lists acceptable modifiers to modify field names. They must be appended after the base name (and wavelength, if any) but before any suffix.

Field modifiers

Field_modifier

Units

Description

_###ang

does not change base field’s units

Collection angle. Append ‘_###ang’ to the end of a field name to indicate the collection angle a measurment (such as VSF) was taken at, where ‘###’ is replaced by the float or integer representation of an angle in degrees

_##cilo

does not change base field’s units

Lower confidence interval, where ## is to be replaced with the percent the confidence interval was computed for

_##ciup

does not change base field’s units

Upper confidence interval, where ## is to be replaced with the percent the confidence interval was computed for

_ex###

does not change base field’s units

Excitation wavelength. Append ‘_ex###’ to the end of a field name to indicate the wavelength of excitation the measurement was taken at, where ‘###’ is replaced by the float or integer represenation of wavelength in nm. May be used in combination with ‘_em###’, as such: ‘<field>_ex###_em###’, where ‘_ex###’ preceeds ‘_em###’

_em###

does not change base field’s units

Emission wavelength. Append ‘_em###’ to the end of a field name to indicate the wavelength of emission the measurement was taken at, where ‘###’ is replaced by the float or integer represenation of wavelength in nm. May be used in combination with ‘_ex###’, as such: ‘<field>_ex###_em###’, where ‘_ex###’ preceeds ‘_em###’

_###filt

does not change base field’s units

Filter size current observed measurements are larger than, where ### is the number of micrometers of the filter size Unless this suffix is used, it is assumed the methodology used a standard filter size. May be used in combination with ‘###prefilt’, as such: ‘<field>_###filt_###prefilt)’

_###prefilt

does not change base field’s units

Filter size current observed measurements are smaller than, where ### is the number of micrometers of the filter size. Unless this suffix is used, measurements are assumed to be from unfiltered or whole water. May be used in combination with ‘###prefilt’, as such: ‘<field>_###filt_###prefilt)’

_###ppt

does not change base field’s units

Parts per thousand, where ### indicates the solution’s concentration that a measurement was taken in, as a floating point number or integer

_###size

does not change base field’s units

Median bin diameter in microns. Used as a suffix for the field ‘PSD’

_stokes1

does not change base field’s units

First Stokes parameter for characterizing polarization

_stokes2

does not change base field’s units

Second Stokes parameter for characterizing polarization

_stokes3

does not change base field’s units

Third Stokes parameter for characterizing polarization

_stokes4

does not change base field’s units

Fourth Stokes parameter for characterizing polarization

Suffixes

The table below lists acceptable suffixes to modify field names. They must be appended at the end of field name, after any modifiers or wavelength. For any field including a suffix, a corresponding field (without suffix) must exist (e.g. if Rrs442.5_sd is provided, Rrs442.5 must exist).

Field suffixes

Field_suffix

Units

Description

_abun

cell/L

Cell abundance for a particular (phytoplankton) taxonomic type

_biovol

m^3/L

Bio-volume for a particular (phytoplankton) taxonomic type

_carbon

ug/L

Carbon concentration for a particular (phytoplankton) taxonomic type

_bincount

none

Number of records averaged into a bin or reported measurement specific to the prefix that _bincount is attached to. The field bincount can simply be used if the bincount applies to all forms of data in the file but this field suffix (i.e. ‘<field>_bincount’) can be used multiple times in the same file for field-specific numbers

_quality

none

An analyst-defined quality flag that is relevant to the base field name. A definition of the quality flags should be provided as metadata header comments and within accompanying documentation files.

_cv

unitless

Coefficient of Variation

_sd

same as base field’s units

Standard Deviation

_se

same as base field’s units

Standard Error

_qa

none

added by OCDB staff, it is set to True when measurement pass internal quality checked and will be considered for matchups